The Lynx Smart BMS is a dedicated Battery Management System for Victron Lithium Smart Batteries. There are multiple BMS-es available for our Smart Lithium series of batteries, and the Lynx Smart is the most feature rich and complete option. It is available in two versions: 500A (with M8 busbar connections) and 1000A (with M10 busbar connections).
The main features are:
Applications
More about Victron:
Victron Energy has a strong, unrivalled reputation for technical innovation, reliability, and build quality. Their products are widely considered to be a professional choice for independent electric power. Efficiently combining two or more distinct power sources is what they do best. Their products include sinewave inverters, sinewave inverters/chargers, battery chargers, DC/DC converters, transfer switches, battery monitors and more.
| Brand | Victron |
| Battery voltage range | 9 – 60 VDC |
| Maximum input voltage | 75 VDC |
| Supported system voltages | 12, 24 or 48 V |
| Reverse polarity protection | No |
| Main safety contactor continuous current rating | 1000 A continuous |
| Main safety contactor peak current rating | 1200 A for 5 minutes |
| Power consumption OFF mode | 0.3 mA for all system voltages |
| Power consumption in Standby mode | Approximately 0.6 W (50 mA at 12 V) |
| Power consumption in ON mode | Approximately 4.2 W (350 mA at 12 V) depending on the state of the relays |
| Minimum load resistance for pre-charging | 10 Ω and above for 12 V systems 20 Ω and above for 24 V and 48 V systems |
| AUX output maximum current rating | 1.1 A continuous, protected by resettable fuse |
| Allow-to-charge port Maximum current rating | 0.5 A at 60 VDC, protected by resettable fuse |
| Allow-to-discharge port Maximum current rating | 0.5 A at 60VDC, protected by resettable fuse |
| Alarm relay (SPDT) Maximum current rating | 2 A at 60 VDC |
| Busbar | M10 (Torque: 33 Nm) (17 Nm for units with a serial number before HQ2340XXXX) |
| VE.Can | RJ45 |
| I/O | Removable multi-connector with screw terminals |
| Battery BTV cables | Male and female circular 3-pole connector with M8 screw ring Up to 20 batteries can be connected in one system |
| Lynx Distributor fuse monitoring (up to 4 modules) | RJ10 (cable ships with each Lynx Distributor) |
| Enclosure material | ABS |
| Enclosure dimensions (h x w x d) | 230 x 180 x 100 mm |
| Unit weight | 2.7 kg |
| Busbar material | Tinned copper |
| Busbar dimensions (h x w) | 8 x 30 mm |
| Operating temperature range | -40 °C to +60 °C |
| Storage temperature range | -40 °C to +60 °C |
| Humidity | Max. 95 % (non-condensing) |
| Protection class | IP22 |
| Safety | EN-IEC 63000:2018 |
| EMC | EN-IEC 61000-6-3:2007/A1:2011/AC:2012 |
| QMS | NEN-EN-ISO 9001:2015 |